BOFAS News & Events

This pages lists all the latest news and upcoming events.

 

To access 'Foot Print' (the BOFAS Bulletin) please click here (members only)

 

Latest News

Annual Meeting 2021 - Recap

The 2021 Annual Meeting is over, but click here if you missed it!

We hope you enjoyed the 2021 Virtual Annual meeting, but if you could not make it, it's available for members free of charge! Follow the link to view the programme and recordings. 

12345678

 

BOFAS Hosted Events

BOFAS Principles Course - Dubai

The aim is to give Overseas Trainee Orthopaedic Surgeons a solid grounding in the principles and the decision making in Foot & Ankle Surgery.

There is an emphasis on clinical examination of cases, small group discussions and learning surgical approaches in the cadaver lab.

This is the first course BOFAS is running in UAE and the aim is to expand the Foot and Ankle education and training in the Middle East and Gulf area.

Venue - Le Meridien, Dubai, United Arab Emirates

Documents to download

BOFAS Principles Course Taunton

These courses are aimed at Higher Surgical Trainees / ST3 onwards and are designed to teach the core of Foot and Ankle surgery in an informal and interactive environment. The emphasis is on clinical examination cases, discussion groups and typical day-to-day clinic scenarios. Although not an exam preparation course, content is taught to the standard expected in the FRCS(Tr & Orth) exam; that of a day-one non-specialist orthopaedic consultant. Applications will open on 1st September 2023.

Venue - Taunton (TBC)

 

 

Documents to download


 

BOFAS Affiliated Courses

Other External Events / Courses

Togay Koç
/ Categories: Abstracts, 2015, Podium

The Zenith total ankle replacement: early to mid-term results in 155 cases

R. Walter, W. Harries, S. Hepple, I. Winson

Introduction: The ZenithTM total ankle replacement (Corin, Cirencester) is a mobile-bearing implant based on the Buechal Pappas design. Key features are the simple fully-jigged instrumentation aiming to improve accuracy and reproducibility of implant positioning, cementless calcium phosphate coated surfaces for improved early osseointegration, and titanium nitride-coated bearing surfaces to resist wear. We present early to mid-term survival data for 155 total ankle replacements implanted by three surgeons in our institute.

Methods: Case records of all patients undergoing ZenithTM Total Ankle Replacement by three senior surgeons, including a member of the design team, between 2007 and 2014 were examined. Patients were examined clinically and radiographically annually after the early postoperative period. The primary outcome measure was implant survival. Secondary outcome measures included complication rates, parameters of radiographic alignment, and radiographic evidence of cysts and loosening.

Results: One hundred and fifty-five cases were performed for a mixture of primary pathologies, predominantly primary or posttraumatic arthrosis. Mean follow-up was 50 months. Implant survival was 99.0% at 3 years (n=103), 94.0% at 5 years (n=50), and 93.8% at 7 years (n=16). One patient was revised to arthrodesis for aseptic loosening, one arthrodesis was performed for periprosthetic infection with loosening, and one below-knee amputation was performed for chronic pain. Three cases underwent further surgery to address cysts, and 7 malleolar fractures were reported. Medial gutter pain was experienced by 9% of patients.

Conclusions: Overall, our data show excellent early and mid-term survivorship for the ZenithTM Total Ankle Replacement. Simple fully-jigged instrumentation allows accurate and reproducible implant alignment.

 

Print
669